3.
Never operate this product if:
a.
It has a damaged power cord or plug.
b.
It is not working properly.
c.
It has been dropped or damaged.
d.
It has been dropped into water. Return the product to an authorized DeVilbiss service center for examination and
repair.
4.
Keep the power cord away from heated surfaces.
5.
Never use while drowsy or asleep.
INTERNATIONAL TRAVEL
The suction unit is equipped with an AC to DC Adapter/Charger allowing operation on any AC voltage (100-240 VAC, 47-63
Hz). However the correct power cord must be used to connect to adaptable wall power. Your unit is approved for use on
commercial aircraft; specific standards are listed in the Specifications in this guide. Certificate is available upon request; if
needed, contact your provider for a copy of approval letter before travel.
NOTE-Check power cord for adaptability before using.
INTRODUCTION
Your DeVilbiss Suction Unit is a compact medical suctioning device which has been designed for reliable, portable
operation. Following the recommended operating and maintenance procedures outlined in this instruction guide will
maximize the life of this product.
Intended Use Statement
The device is to be used to remove fluids from the airway or respiratory support system and infectious materials from
wounds. The device creates a negative pressure (vacuum) that draws fluids through disposable tubing that is connected to
a collection container. The fluids are trapped in the collection container for proper disposal. It is for use on the order of a
physician only.
Contraindications
The Vacu-Aide Compact Suction Unit should not be used for:
•
thoracic drainage
•
nasogastric suction
DANGER
The DeVilbiss Vacu-Aide is a vacuum suction device designed for the collection of nonflammable fluid materials in
medical applications only. Improper use during medical applications can cause injury or death. For all medical
applications:
1.
All suctioning should be done in strict accordance with appropriate procedures that have been established by a
licensed medical authority.
2.
Some attachments or accessories may not fit the tubing supplied. All attachments or accessories should be checked
prior to use to assure proper fit.
IMPORTANT PARTS
Inspect the suction unit and all parts before use.
1.
Vacuum Regulator Knob (on side)
2.
Bacteria Filter (non-sterile)
3.
Vacuum Inlet Port (behind filter)
4.
Display Panel (top of unit)
5.
725 ml Reusable Container with Lid/Elbow
Assembly
6.
DC Power Input (on side)
7.
Battery Door
8.
Unit Carry Handle/Catheter Holder
9.
6' (1.8m) Patient Tubing (not shown)
10. AC to DC Adapter/Charger (not shown)
11. 12V DC Power Cord (not shown)
12. High Capacity Rechargeable Battery (not
shown)
13. Carry Case with Shoulder Strap (not shown)
EN - 4
2
3
1
8
4
5
6
7
A-7310