EN
Never stretch the power cable. Place the machine in a ventilated room. When using the appliance, never obstruct the
air inlet when the appliance in on , so as not to compromise its performance and safety.
For the final disposal of this appliance, comply with local regulations in force.
2. GENERAL TECHNICAL FEATURES
2.1. DATA SHEET
Model
Cooling capacity
8 Kg (+3 °C)
3 x 1/1GN
5 Kg (-18 °C)
12 Kg (+3 °C)
5 x 1/1 GN
+ 60x40
8 Kg (-18 °C)
25 Kg (+3 °C)
10 x 1/1 GN
+ 60x40
15 Kg (-18 °C)
3. INSTRUCTIONS FOR THE INSTALLER
Read carefully all the instructions in this manual, because they give important suggestions about the right instal-
lation and use of the appliance.
3.1. CONTROLS AT RECEPTION
The appliance are shipped in appropriate protective packing.
On arrival, check that the appliance has not incurred in transport damage and that it is complete according to
the order.
In the event of visible damage immediately note the damage on the transport documents with the following
wording: "RECEIVED WITH RESERVE FOR EVIDENT DAMAGE OF PACKING".
3.2. HANDLING AND PLACING
IMPORTANT: All the operations indicated below must be performed in respect of the existing safety regulations, both
for the equipment in use and for the operating procedures.
ATTENTION: Before beginning handling operations ensure that the lifting capacity is enough for the appliance in
question.
Handling with fork lift or similar (A); Insert the forks into the side or back of the wooden pallet supplied with the
appliance, begin lifting checking that the appliance is in stable equilibrium.
When insert the lifting device, pay attention to the power supply cable and the position of the feet.
ATTENTION: during handling do not tip or turn over.
WARNING: the respect of the recommendations printed on the outside of the packing is a guarantee of a sound
physical and operating condition of the appliance, all to the advantage of the end-user.
THEREFORE THE FOLLOWING IS RECOMMENDED:
• HANDLE WITH CARE
• KEEP DRY
• STACKING OF OTHER OBJECTS ON THE APPLIANCE MUST BE ABSOLUTELY AVOIDED
• DO NOT COMPRESS SIDEWAYS
• DO NOT TURN UPSIDE DOWN
• STACKING OF BLAST CHILLERS IS PERMITTED: READ CAREFULLY THE MAXIMUM PIECES' NUMBER INDICATED ON
THE EMBALLAGE.
Lift the appliance to separate it from the pallet.
Remove the packing (B) and the protective film avoid using abrasive brushes or other damaging materials for the
appliance's surfaces (C).
Check that the appliance is perfectly levelled.
Regulate the adjustable feet if necessary. Place the appliance away from heat sources and in a ventilated room.
When using the appliance, never obstruct the air inlet when the appliance in on, so as not to compromise its
performance and safety.
Placing the appliance in a site easy to join, so every type of maintenance, control and repair may be done easily.
Voltage
Gas
Cooling pow.
230 V
R452A
0.46 Kw
1N 50 Hz
230 V
R452A
0.65 Kw
1N 50 Hz
230 V
R452A
1.17 kW
1N 50 Hz
16
Tot. pow. Packed vol.
0.5 Kw
0.37 m
3
0.65 Kw
0.68 m
3
1.21 kW
1.19 m
3
Gross Weight
64 kg
86 kg
118 kg