POINT A -
ELECTRIC CONNECTIONS
J8
J7
J6
J5
J4
J3
J2
J1
F1
PROG
J1
L1 - N
J2
U
J11
V-W
J12
R-AUX
J3
SIGNAL
COM A+
J13
A+ COM
J4
A-
A+ TEST
COM A+
J14
B.I.O.
PED.
J5
START
CLOSE
OPEN
COM A+
STOP
PHOT 1
J6
J15
PHOT 2
EDGE 1
EDGE 2
J16
COM A+
J7
J17
LIMIT SWITCH
J8
PROBE
J9
ENCODER
J10
J11
APP+
J12
APP
SERIAL COM /
J13
SYNC
J14
-
J15
RADIO
J16
RADIO
J17
PROG.
TCA
LOW SP
TORQUE
F1
T5A
31
230 Vac 50/60 Hz power supply (120 Vac 60 Hz upon
request)
Flashing light (max 40 W )
Motor common connection
Motor phases and capacitor connections
Auxiliary relay contact (NO) Max 700 W
Gate open state (24 Vdc 3 W max)
Common contacts / Positive 24 Vdc
+ 24 Vdc accessories power supply
- 24 Vdc accessories power supply
+ 24 Vdc photocells self-test power supply
Common contacts / Positive 24 Vdc
Contact (NO) dedicated to a clock
Pedestrian opening contact (NO)
Single pulse contact (NO)
Closing impulse contact (NO)
Opening impulse contact (NO)
Common contacts / Positive 24 Vdc
STOP impulse contact (NC)
Photocells contact 1 (NC)
Photocells contact 2 (NC)
Edge 1 contact (NC)
Edge 2 contact (NC)
Common contacts / Positive 24 Vdc
Limit switches that cuts OFF the motor
Temperature sensor cable connection probe (code
ACG4665 optional)
Encoder connection (K PLUS operators)
RS485 termination of J11
Connector for APP+ card
Connector for APP card
Connector for serial connection
-
Connector for radio module ACG8069
Connector for radio receiver RIB, 24 Vdc supply
433 MHz Radio antenna
Programming button
Trimmer for automatic closing time adjustment
(DISABLED DEFAULT AND DL11 LED OFF)
Electronic regulator for low speed on approach
Electronic torque regulator
Fuse for motor protection
G
B

Publicidad

loading

Este manual también es adecuado para:

Super 2200 fcmAa31004Aa31008