FreshWell3000
Problem
Cause
No heating
The under-bench air conditioner is
capacity
not set to heating.
The ambient temperature is below
0 °C.
The temperature set is lower than the
room temperature.
The ambient temperature is higher
than 31 °C.
The thermal protection is defective.
The compressor is damaged.
The refrigerating agent filling is
insufficient.
The heat exchange coils are pol-
luted.
The external blower is defective.
Low air output
The air filter is obstructed.
The heat exchange coils are pol-
luted.
The internal blower is defective.
Water enters the
The condensation water drainage
vehicle
openings are clogged up.
The seals are damaged.
The under-
No supply voltage (230 Vw)
bench air condi-
connected.
tioner does not
The voltage is too low (under
switch on.
200 Vw).
The voltage converter is defective.
The defective thermal protection is
defective.
The electrical fuse of the power
supply is too low.
EN
Troubleshooting
Remedy
➤ Set the under-bench air
conditioner to heating.
The under-bench air conditioner
is only designed for ambient
temperatures higher than 0 °C.
➤ Select a higher temperature.
The temperature is adjustable
between 16 °C and 31 °C.
➤ Contact an authorized service
agent.
➤ Clean the air filter.
➤ Contact an authorized service
agent.
➤ Clean the drainage openings
for condensation water.
➤ Contact an authorized service
agent.
➤ Check the power supply.
➤ Contact an authorized service
agent.
➤ Check the electrical fuse of
the power supply.
27