ProCore Edge North America
1.
Remove the six M5 screws on the top panel
of the charger (Figure 2) with a TORX TX25
and remove the panel.
2.
Connect an NEC-approved AC shielded input
cable (such as type SOOW) or conduit to the
charger through the AC service entrance,
which is the hole located in the top left corner
of the charger.
Use the appropriate minimum wire size
(gauge) or larger for the maximum kilowatt
rating of the charger. See section 2 for the
minimum fitted AC input wire size (AWG)
per NEC.
The AC service entrance
provides two hole sizes.
3.
Use the provided round panel
to use the smaller hole size, or
remove the panel to use the
larger hole size.
4.
Place an appropriate cable
gland or conduit clamp in the
AC service entrance hole to
secure the cable or conduit.
5.
Connect the three-phase AC
input power cables.
6.
Ensure the ground and power
cables are properly stripped of
approximately ½ in. (12.7 mm)
of insulation from the ends.
Loosen the terminal screws
with a flathead screwdriver and
insert the stripped ends of the
ground and power cables.
7.
Re-tighten the screws. The
three-phase input is not phase
specific, so the AC line input
positions are interchangeable.
8.
Ensure the cable gland or
conduit clamp are properly
tightened.
31241-76-0104
Ground and Power Cables
AC Service
Entrance
Fig. 12 – Three-Bay AC Service Entrance
Ground and Power Cables
AC Service
Entrance
Fig. 13 – Five-Bay AC Service Entrance
Page 10 of 12
Fig. 11 – AC Service Entrance
Torque Specifications Label