Installation Guide
3.7 – DC Battery Connection
DANGER
Only qualified service personnel should remove the DC output power cable panel and
service the charger. This device does not contain any user serviceable parts.
DANGER
RISK OF ELECTRIC SHOCK
DANGER
DO NOT ATTEMPT TO CHARGE NON-RECHARGEABLE BATTERIES.
Fast chargers are designed to be used only for charging rechargeable batteries.
Attempting to charge non-rechargeable batteries could lead to death or injury from
exploding batteries.
DANGER
BATTERIES CAN BE DANGEROUS.
Batteries generate explosive gases during normal charging and usage. Always follow
charging instructions and those of the battery manufacturer to reduce the risk of battery
explosion.
WARNING
FLAMMABLE
WARNING
Connecting a high-voltage battery (80V or higher) to a low-range charger (24V - 48V)
may damage the charger. Use voltage-keyed connectors on the chargers and batteries
if your facility has mixed battery voltages.
CAUTION
Only use copper wires.
NOTE
Three- and five-bay cabinets have field wiring terminal blocks that can accept a input
wire gauge range from 10 to 14 AWG (2.5 to 6 mm
screw-tightening is 22.2 in-lbs (2.5 Nm) and 26.4 in-lbs (3 Nm) of torque, respectively.
Webasto Charging Systems, Inc.
•
Electric shock can cause serious injury or death.
•
Do not touch the uninsulated portion of the output power cable, battery
connector or other live electrical parts, or uninsulated battery terminals.
•
Disconnect the charger from the input power and battery before servicing.
•
Keep batteries away from fire.
•
Do not smoke, use an open flame, or cause sparks near a battery.
Page 11 of 12
ProCore Edge North America
). The minimum and maximum
2