Checking the remaining battery
capacity (BL1460A)
1
2
► 1 . Indicator lamps 2. Check button
NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
When charging
When the charging begins, the first (far left) indicating
lamp begins to flicker. Then, as charging proceeds, the
other lamps light, one after the other, to indicate the
battery capacity.
NOTE: If the indicator lamp does not turn on or flicker
when charging, the battery may be faulty. In this case,
ask your local service center.
When using
When the tool is switched on, the lamps will light to
indicate the remaining battery capacity. When the tool is
switched off, the light goes out after approx. 5 seconds.
When pushing the check button with the tool switched
off, the indicator lamps turn on for approx. 5 seconds to
show battery capacity.
If the orange lamp flickers, the tool stops because of little
remaining battery capacity (Auto-stop mechanism). Charge the
battery cartridge or use a charged battery cartridge at this time.
When the tool is used with the battery that has not been
used for a long time and is switched on, no lamps may
light up. The tool stops because of little remaining bat-
tery capacity at this time. Charge the battery properly.
Battery protection system (BL1460A)
The tool is equipped with a battery protection system. This system
automatically cuts off power to the motor to extend battery life.
The tool will automatically stop during operation if the tool
and/or battery are placed under the following conditions:
•
Overloaded:
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, release the switch trigger on
the tool and stop the application that caused
the tool to become overloaded. Then pull the
switch trigger again to restart.
If the tool does not start, the battery is over-
heated. In this situation, let the battery cool
before pulling the switch trigger again.
•
Low battery voltage:
70%-100%
50%-70%
35%-50%
Switch action
20%-35%
0%-20%
► 1 . Switch trigger
CAUTION:
•
Before inserting the battery cartridge into the
tool, always check to see that the switch trigger
actuates properly and returns to the "OFF"
position when released.
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
Reversing switch action
A
► 1 . Reversing switch lever
CAUTION:
•
Always check the direction of rotation before operation.
•
Use the reversing switch only after the tool comes
to a complete stop. Changing the direction of
rotation before the tool stops may damage the tool.
•
When not operating the tool, always set the
reversing switch lever to the neutral position.
6 ENGLISH
When the battery capacity is not enough, the
tool stops automatically and the battery indica-
tor shows following state. In this case, remove
the battery from the tool and charge the battery.
BL1460A
1
1
B