Know Your Air Compressor
READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.
Description of Operation
Become familiar with these controls before operating the unit.
On/Auto/Off Switch: Turn this switch ON to provide automatic power to the
pressure switch and OFF to remove
power at the end of each use.
Pressure Switch: The pressure switch
automatically starts the motor when the
air tank pressure drops below the
factory set "cut-in" pressure. It stops the
motor when the air tank pressure
reaches the factory set "cut-out"
pressure.
Safety Valve: If the pressure switch
does not shut off the air compressor at
its "cut-out" pressure setting, the safety
valve will protect against high pressure
by "popping out" at its factory set
pressure (slightly higher than the pressure switch "cut-out" setting).
Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure
available at the outlet side of the regulator. This pressure is controlled by the
regulator and is always less than or equal to the tank pressure.
Tank Pressure Gauge: The tank pressure gauge indicates the reserve air
pressure in the tank.
Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull
the knob out and turn clockwise to increase pressure and counterclockwise to
decrease pressure. When the desired pressure is reached push knob in to lock
in place.
Universal Quick-Connect Body: The universal quick-connect body accepts
the three most popular styles of quick-connect plugs- Industrial, automotive
(Tru-flate), and ARO. One hand push-to-connect operation makes connections
simple and easy. The two quick connect bodies allow the use of two tools at
the same time.
Drain Valve: The drain valve is located at the
base of the air tank and is used to drain
condensation at the end of each use.
Cooling System (not shown): This compressor
contains an advanced design cooling system. At
the heart of this cooling system is an engineered
fan. It is perfectly normal for this fan to blow air over the pump head, cylinder
sleeve, and crankcase. You know the cooling system is working when air is
being expelled.
Air Compressor Pump (not shown): Compresses air into the air tank.
Working air is not available until the compressor has raised the air tank
pressure above that required at the air outlet.
A02250
OPERATION
Tank
Pressure
Gauge
On/Auto/Off
Switch
Outlet
Pressure
Gauge
12- ENG
Pressure
Switch
Universal Quick-
Regulator
Connect Body
Drain Valve
Safety Valve