Electrical and Structural Requirements (Continued)
Deep box with brace (Figure 3)
Paired with a deep box, this hanger is meant to span
between two joists and takes the place of wooden blocking.
To reduce the risk of fire, electric shock, or personal injury,
mount to outlet box marked acceptable for fan support of
15.9 kg (35 lbs) or less and use mounting screws provided
with the outlet box. Most outlet boxes commonly used for
the support of luminaires are not acceptable for fan support
and may need to be replaced, consult a qualified electrician
if in doubt.
If your fan is to replace an existing light fixture, turn
electricity off at the main fuse box at this time and remove
the existing light fixture.
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned off
at the main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
To avoid fire or shock, follow all wiring instructions
carefully. Any electrical work not described in these
instructions should be done or approved by a licensed
electrician.
Do not operate this fan with a variable (Rheostat) wall
controller or dimmer switch. Doing so could result in
damage to the ceiling fan's remote control unit.
WARNING
WARNING
WARNING
WARNING
CEILING
6
CEILING JOIST
Figure 3
OUTLET BOX