Descargar Imprimir esta página

Holmatro IPU-S Serie Manual página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
3.5.2
Separately available
/i
Description
Connection block
Pressure control valve
Carrying handle kit for 6 and 12 litre pumps
Carrying handle kit for 25 litre pumps
Protective frame for 6, 12, 25 and 50 litre pumps
Wheel set for 25 and 50 litre pumps
Cover plate for protective frame
Carriage frame for 25 and 50 litre pumps
4
Preparation for first use
4.1
General
Check the equipment for completeness and damage. Do not use the equipment if it is damaged; in
that case contact the Holmatro dealer.
Check whether all accessories are available.
Make sure the pump is in a horizontal position.
4.2
Check the hydraulic oil usage
CAUTION
Use hydraulic oil with the correct specifications and make sure no dirt or dust enters the
hydraulic tank to prevent damage to the pump and tools.
If the pump is used at temperatures above -10 °C:
1. Check the hydraulic oil level.
2. If necessary, add ISO-L HV VG 36 oil. (for VM43L: ISO-L HV VG 15 oil only)
If the pump is used at temperatures below -10 °C:
Replace the hydraulic oil with ISO-L HV VG 15 oil because the pump is delivered with ISO-L
HV VG 36 hydraulic oil.
4.3
Check the electric motor
Check whether the voltage and power rating of the electrical power is in accordance with that of the
motor (see specifications on the motor nameplate).
DANGER
A licensed electrician is required to replace an electrical power connector.
Fit the correct electrical power connector, if necessary.
NOTICE
The direction of rotation is irrelevant due to the design of the pump.
IPU-S
916.000.972_002
Type
M-301B
M-303
EN
Part number
100.182.088
100.181.303
100.151.053
100.151.054
100.151.056
100.151.039
100.151.040
100.151.038
27

Publicidad

loading