English
Technical Information
Water pressure
recommended
maximum
Hot water temp.
recommended
maximum
Flow rate @ 44 PSI
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
Installation Considerations
• For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
• This trim is for use with iBox Universal Plus model
01850181 (not included).
• Please read over these instructions thoroughly
before beginning installation. Make sure that
you have all tools and supplies needed to
complete the installation.
• This product is for use with shower heads rated
at 1.1 GPM (4.2 L/min) or higher.
• To prevent scald injury, the maximum output
temperature of the shower mixing valve must be
no higher than 120°F (49°C). In Massachusetts,
the maximum output temperature can be no
higher than 112° F (44°C).
2
15 - 75 PSI (0.1-0.5 MPa)
145 PSI (1 MPa)
120°-140° F (49°- 60°C)*
176°F (80° C)*
5.5 GPM (20.8 l/min)
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.
The rotational limit stop (see page 23)
To reduce the risk of scald injur y,
adjust the rotational limit stop if:
• The maximum output temperature is greater
than 120°F (49°C) or that permitted by local
plumbing code
• The temperature of the incoming hot or cold
water supply changes seasonally, or if changes
are made to the water heater.