• Fill with hydraulic oil, the manufacturer recom-
mends a high value hydraulic oil with a viscosity
of 32 cst. The required oil volume is approx. 14
litres. After filling, the oil must be between the
marks on the oil dipstick or approx. 2 cm below
the oil filling supports (11).
13
14
11
11 Oil filling supports
12 A1
14 N1
• Move the lifting upwards to approx. 1,500 mm
• Check the alignment of the base plates again
and anchor the lift. Holes for floor anchoring
are to be placed through the holes in the base
plates.
Clean the bore holes by blowing them out with
air. Insert safety anchors into the holes.
The
manufacturer
proved safety anchors and to follow anchor
manufacturer's instructions.
Before anchoring the lift, check whether the con-
crete is of quality C20/25 up to the finishing level
of the completed floor. In this case, take the
anchor length from the anchor manufacturer's
data sheet. If there is a floor covering (tiles,
screed) on the weight bearing concrete, the
thickness of this covering must be determined.
• Anchor the unit to the floor.
• Align the lift
To prevent hollow spaces, correct any uneven-
ness in the floor by putting shims under the base
frame (e.g thin metal strips). Use suitable sup-
ports to ensure continuous contact between the
floor and base frame.
20110009 OPI
Version 1.0
12
15
002
13 A2
15 N2
recommends
using
JUMBO LIFT 3200 NT - HYMAX XX 3200 PH
• Tighten safety anchors with torques recommen-
ded by the manufacturer.
Each anchor must be tightened to the required
!
torque. Safe operation of the lift is not guaran-
teed with a lower torque. Follow the instruc-
tions of the anchor manufacturer.
• Move the lift upwards and downwards several
times, then check the anchors with the torque
wrench and tighten if required. Check the hy-
draulic lines for leak-tightness.
• Balance the lift again if required.
• Mount all hose covers.
• Anchor the foot bumpers included beside the lift
on the floor. For this, lower the lift to the lowest
position. Position the foot bumpers and perma-
nently anchor them Distance between the drive
in rails and the foot bumpers approx. 20 mm (foot
bumpers may not touch the drive in rails.
20 mm
Position of the foot bumpers
ap-
4.3

Fill and vent the hydraulic systems

• The lift is factory pre-installed; meaning the hoses
and pipe connections are properly assigned.
Finally, check the power connection, check for
correct hydraulic oil in the proper volume and
leak-tightness of the connection when setting up
the lift.
If the hose connections are still open, e.g. for the
purposes of hose extension, then air may be ent-
rapped resulting in start up problems or challen-
ges with smooth running.
Check and ensure proper allocation of hose
connections.
016
49