If the machine is not used for some time, remove the squeegee, brushes and drive disks,
wash them and put them away in a dry place (preferably in a bag or wrapped in plastic
film) away from dust. Park the machine with the parking brake on.
Make sure the tanks are completely empty and perfectly clean.
Disconnect the machine from the power supply.
Charge the batteries completely before storing them. During long periods of inactivity,
you should charge the batteries regularly (at least once every two months) to keep them
constantly at maximum charge.
If you do not charge the batteries regularly, they may be irrevocably damaged.
8.
The batteries give off flammable fumes. Put out all fires and hot embers before
Perform the operations described above in a ventilated room.
To avoid permanent damage to the batteries, do not run them down completely.
Remember that when the battery voltage displayed drops to about 29V, the batteries
must be charged.
8.1.
Charging procedure
• connect the battery charger connector to the battery wiring connector;
In the case of gel batteries, use a charger specific for gel batteries only.
• Charge the batteries as described in the battery charger manual;
• at the end of charging, disconnect the connectors;
Never perform any maintenance operations without first disconnecting the
Maintenance on the electrical circuit and all other operations not explicitly
described in this manual must be performed by specialised personnel only, in
compliance with current safety legislation and as described in the maintenance
7.
PERIODS OF INACTIVITY
IMPORTANT
BATTERY MAINTENANCE AND CHARGING
! DANGER
Do not check the batteries by sparking.
checking or topping up the batteries.
IMPORTANT
9.
MAINTENANCE INSTRUCTIONS
! DANGER
batteries.
manual.
ENGLISH