8.3. Technical data MT-HV
Supply voltage
Power input
Current draw
Battery type
Ambient temperature
Suitable for humid environment?
Use at high altitude
Relative air humidity
Continuous operation
Weight
Dimensions
IP degree of protection
Overload protection
Measuring channels
Measured variables of HV modules
Interfaces
Ranges
Voltage
MT-HV
12...32 V
10...40 W
max. 1 A
RRC2040
Recommended: 10 to 35 °C
Working range: 0 to 45 °C
Storage temperature: -10 to 60 °C
no
max. 2,000 m above NHN (normal height null)
approx. 10 to 90 % (not condensating)
ja
approx. 1.7 kg
300 x 360 x 80 mm (L x W x H)
IP20
max. 1 kV
1 (galvanically isolated)
• High-voltage measurement up to 1 kV
• Potential equalization measurement
• Insulation resistance measurement
• Resistance measurement (service disconnect plug)
• USB-C
• Bluetooth®
• RJ45
• Measuring range: ± 1000 V DC
• Resolution: 0.1 V
• Precision: ± (1 % of reading + 2 digits)
General information | 8.