  • ESPAÑOL, página 123
8. | General information
Ranges
Insulation resistance measurement
Resistance (service disconnect plug)
Potential equalization measurement
High-voltage test lead
Red
black
8.4. Technical Data of the MT 77
Supply voltage
Power input
Current draw
Ambient temperature
Suitable for humid environment?
Use at high altitude
Relative air humidity
60
• Measuring range: 10k...10 GΩ
• Test voltage: variably adjustable to 1000 V DC in steps of 10 V
• Resolution: 0.1
• Precision: ± (3 % of reading + 3 digits)
• Measuring range: 0...10 Ω
• Resolution: 0,01 Ω
• Measuring current: 200 mA
• Precision: ± (2.5 % of reading + 4 digits)
• Measuring range: 0...10 Ω
• Resolution: 0,01 Ω
• Measuring current: 200 mA
• Precision: ± (2.5 % of reading + 4 digits)
• Length: 1500 mm
• Handpiece with function button
• With 4 mm test connection for manufacturer-specific test adapters
• incl. removable test probe
• Length: 1500 mm
• Handpiece
• With 4 mm test connection for manufacturer-specific test adapters
• incl. removable test probe
5 V
(through module interface)
0 W
max. 2 A
Recommended: 10 to 35 °C
Working range: 0 to 45 °C
Storage temperature: -10 to 60 °C
no
max. 2,000 m above NHN (normal height null)
approx. 10 to 90 % (not condensating)
Hella Gutmann