6.0 Electrical Connection
DANGER
DANGER
CAUTION
6.1. Cable Requirements for Connection
No. Cable
1
Battery power
cables with inverter
2
Battery
communication
cable with inverter
3₁
Signal cable
4
PV Power
cable
5₂
Signal cable
6₃
Signal cable
7
AC power cable for
backup
8
AC power cable for
grid
9
PE cable
© 2023 Maxeon Solar Technologies, Ltd. All rights reserved. | 547143 Revision B - June 2023
Specifications included in this document are subject to change without notice
The energy storage system damage caused by incorrect cable connections
is not covered under any warranty. Only certified electricians are allowed
to connect cables. Operation personnel must wear proper PPE when
connecting cables.
Before connecting cables, ensure that all breakers and switches of the
energy storage system are set to OFF. Otherwise, the danger voltage of
the system may result in electric shocks.
The cable colors shown in the electrical connection diagrams provided in
this chapter are for reference only. Select cables in accordance with local
cable specifications (green-and-yellow cables are only used for PE).
Type
Standard PV cable in the
industry
Standard network cable
in the industry
Standard network cable
in the industry
Standard PV cable in the
industry (recommended
type: PV1-F)
Standard network
cable in the industry
(recommended type:
C-Bus cable)
Multiple-core outdoor
shielded twisted pair
cable
Three-core (L, N and PE)
outdoor copper cable
Three-core (L, N and PE)
outdoor copper cable
Single-core outdoor
copper cable
Conductor
Outer
Cross
Diam.
Section Area
16mm²
N/A
0.12-0.20mm² N/A
0.12-0.20mm² N/A
4-6mm²
5.5-9mm
0.12-0.20mm² 4-6mm
0.1~1.3mm²
4-6mm
4-6mm²
10-14mm Purchased by
6–10mm²
9-18mm
4-10mm²
N/A
Source
Delivered with
the inverter
Delivered with
the inverter
Delivered with
the inverter
Purchased by
the installer
Purchased by
the installer
Purchased by
the installer
the installer
Purchased by
the installer
Purchased by
the installer
31

Publicidad

loading

Este manual también es adecuado para:

Reserve-inv-1-p5-l1-intReserve-bat-1-dc-10.1-int