Descargar Imprimir esta página

Best CC34ISB Manual De Instrucciones página 50

Publicidad

Idiomas disponibles

Idiomas disponibles

CONNECT THE WIRING
WARNING: All electrical wiring
should be done by a qualified person (s)
in accordance with all applicable codes
and standards. This range hood must be
properly grounded.
Do not turn blower on at the service panel until
all wires have been connected.
1. From the room interior, pull down both
closure panels. Fig. 9.
2. Remove (4) screws from the electrical
compartment access panel. Slide the panel
sideways to expose the electrical wiring box.
BLOWER CONNECTION AT THE HOOD
1. Run 2-wire plus ground power cable to a ¾"
knockout located on the back of the hood.
Fig. 10.
2. Remove a ¾" electrical knockout from the
back of the hood.
5. From the electrical box marked "MOTOR
CONNECTION" , remove (2) screws that
secure the cover to the metal wiring box.
Fig. 11.
6. Pull 6" of cable into the box and secure with
an appropriate cable clamp.
7. Make electrical connections inside the "MO-
TOR CONNECTION" box. Connect white-
to-white, red-to-black and green-to-ground.
8. Replace the wiring box cover and the
screws. Make sure wires are not pinched
between the cover and box.
CONNECTIONS AT EXTERIOR OR IN-LINE
BLOWER
1. Make electrical connections at the exterior
or in-line blower (see blower instructions).
BLOWER CONNECTION AT THE HOOD
1. Run 2-wire plus ground, 120 VAC electrical
power cable to a ¾" knockout located on the
back of the hood. Fig. 10.
2. Remove a ¾" electrical knockout from the
back of the hood.
3. From the electrical box marked "120VAC
INPUT" , remove (2) screws that secure the
cover to the metal wiring box. Fig. 11.
4. Pull 6" of cable into the box and secure with
an appropriate cable clamp.
5. Make electrical connections inside the
"120VAC INPUT" box. Connect white-to-
white, black-to-black and green-to-ground.
6. Replace the wiring box cover and the
screws. Make sure wires are not pinched
between the cover and box.
7. Replace the electrical compartments ac-
cess panel and (4) screws.
CLOSURE PANELS
2-WIRE PLUS
GROUND
120 VAC
LINE IN
KNOCKOUTS
BLO WER AND POWER CONNECTION AT HOOD
POWER CONNECTION
CONNECT:
WHITE-TO-WHITE
BLACK-TO-BLACK
GREEN-TO-GROUND
120VAC 60Hz
LINE-IN
BOX MARKED
"120VAC INPUT"
- 10 -
FIG. 9
2-WIRE PLUS
GROUND
BLOWER
CONNECTION
FIG. 10
BLOWER CONNECTION
CONNECT:
WHITE-TO-WHITE
RED-TO-BLACK
GREEN-TO-GROUND
FROM EXTERIOR
OR IN-LINE
BLOWER
MAIN
SWITCH
BOX MARKED
"MOTOR CONNECTION"
FIG. 11

Publicidad

loading