Measurement of voltage with alternating current and direct current
1) Connect the black test lead to the "COM" terminal and the red test lead to the "V Hz" terminal.
2) Set the selector to "V
test AC voltage, press the "SELECT" button.
3) Connect the test leads to the source or the load under measurement.
4) The measurement value will be displayed. The polarity of the red wire connection will be indicated
along with the direct current voltage value.
Direct Current Measurement
Set the selector to the desired position. "200 A or 1000 A".
2. Press "REL" in the display will show "0"
Note: It is possible that after a certain period of use the hook has a magnetic force, so that "0" will not
appear on the screen if it happens, press REL and follow these steps
A. Change the direction of the measured current.
B. Open the hook several times.
3. Open the hook by pressing the opening trigger and insert a single cable into the hook.
4. Close the hook and get the reading on the screen.
NOTE: Before performing this measurement, disconnect the test lead for greater safety.
Measurements
". , The display shows the symbol to test direct current voltage, if you want to
Ω
OFF
Ω
V
- - -
CAP
Hz
ºC
- - -
200A
- - -
1000A
400A/
1000A
DH> 2 sec
REL
Hz/Duty
SELECT
RANGE
OFF
V
Ω
- - -
CAP
Hz
ºC
- - -
200A
- - -
1000A
400A/
1000A
DH> 2 sec
REL
Hz/Duty
SELECT
RANGE
8