OWNER'S MANUAL
High-Temp Sump and Light Effluent Pumps
The high-temp sump and light effluent pumps are specifically designed to
handle high-temperature effluent wastewater removal in applications such
as boiler blowdown, sump pit, or transformer vaults. Backed by an energy-
efficient motor with thermal overload protection, these pumps offer man-
ual or automatic switch options and come with a 15-foot power cord.
These submersible effluent pumps are for use in basins or lift stations, and
are suitable for pumping effluent, wastewater, and other non-explosive,
noncorrosive liquids with up to ¾-inch spherical solids and temperatures
up to 200 °F (93.3 °C).
This product is covered by a Limited Warranty for a period of 3 years from
the date of original purchase by the consumer. For complete warranty
information, refer to www.LittleGiant.com.
Specifications
Model
HT-10EN-CIM
HT-10EN-CIA-FS
HT-6EN-CIA-FS
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product's application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions, and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
• Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
• Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri-
cally disconnected.
• If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of
power.
• If the disconnect panel is not accessible, contact the electric company to stop service.
Amps
HP Hz Volts
FLA Start
½
9.5
60
115
⅓
6.5
Watts PSI
Level
in (cm)
950
13
21
(22.86-
35.56)
650
10.8
EN
ON
OFF
Shut
Level
Off
in (cm)
ft (m)
30
9-14
(9.1)
2-4
(5-10.2)
25
(7.62)
English
Discharge
in (mm)
1.5 (38.1)
FNPT