 Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring
tool which may ignite the dust or fumes.
Keep the measuring tool away from cardiac
pacemakers. The magnet inside the measur-
ing tool generates a field that can impair the
function of cardiac pacemakers.
 Keep the measuring tool away from magnetic data me-
dia and magnetically-sensitive equipment. The effect of
the magnet can lead to irreversible data loss.
Technical Data
Cross-line Laser
Article number
Working range
– Standard
– With pulse function
– With laser receiver
Levelling Accuracy
Self-levelling range, typically
Levelling duration, typically
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
C
6
Shortest pulse duration
Tripod mount
Batteries
Operating time, approx.
Automatic switch-off after approx.
Weight according to EPTA-Procedure 01/2003
Dimensions
Degree of protection
The measuring tool can be clearly identified with the serial number 9 on the type plate.
Product Features
The numbering of the product features shown refers to the il-
lustration of the measuring tool on the graphic page.
1 Exit opening for laser beam
2 Pulse-function indicator
3 Pulse-function button
4 Operating mode button
5 Battery indicator
6 Tripod mount 1/4"
7 On/Off switch
8 Battery lid
9 Serial number
10 Laser warning label
Bosch Power Tools
Product Description and Specifica-
tions
Please unfold the fold-out page with the representation of the
measuring tool and leave it unfolded while reading the operat-
ing instructions.
Intended Use
The measuring tool is intended for determining and checking
horizontal and vertical lines.
IP 54 (dust and splash water protected)
11 Latch of battery lid
12 Alignment plate*
13 0° alignment aid on the alignment plate
14 90° alignment aid on the alignment plate
15 45° alignment aid on the alignment plate
16 Pin on the alignment plate
17 Protective pouch*
18 Case*
19 Laser viewing glasses*
20 Measuring plate with stand*
21 Laser receiver*
* The accessories illustrated or described are not included as
standard delivery.
English | 13
GLL2-50 Professional
3601K631..
20 m
15 m
50 m
±0.3 mm/m
±4°
<4 s
–10 °C...+50 °C
–20 °C...+70 °C
90 %
2
635 nm,<1 mW
1
1/1600 s
1/4"
3 x 1.5 V LR6 (AA)
12 h
30 min
0.45 kg
118 x 57 x 89 mm
1 609 92A 0KJ | (6.5.14)