Maintenance:
Only maintenance works described in this instruction
manual may be carried out, all other works must be
performed by an official dealer.
Only use accessories, oils or greases authorized by VITO.
Not doing so may result in personal injuries or damages to
the blower/vacuum cleaner. In case of doubt, you should
contact an official dealer.
For safety reasons, the fuel conductive components (fuel
hoses, tank, tank cap and couplings) should be checked
regularly for damage and leaks. If necessary, they should
be replaced by an official dealer.
Keep warning and information stickers always clean and
legible.
Keep all nuts and bolts well tightened in order to ensure a
safe operation.
If any components or safety devices are removed for
maintenance
tasks,
immediately.
Let the combustion engine cool down before you put the
machine into an enclosed space. During operation, the
exhaust becomes extremely hot and remains so for a few
minutes after switching off the engine. Avoid touching the
exhaust while it is hot.
Never store the blower/vacuum cleaner with petrol in the
tank inside a building. Petrol vapours may come into
contact with flames or sparks and ignite.
Store the blower/vacuum cleaner in a dry area with the fuel
tank empty and the fuel in a well-ventilated compartment.
Avoid places with high humidity to avoid the appearance of
corrosion and rust.
Clean the equipment thoroughly before storage, especially
in winter. Keep the device in a good operating condition.
Make sure the machine is protected against misuse (for
example, by children).
they
must
be
repositioned
Your blower/vacuum cleaner should only be serviced by the
manufacturer's internal service personnel, or other
qualified personnel, replacing any necessary parts with
original parts sourced directly from the manufacturer.
1. Align and fit the upper blow tube (2) to the air outlet of
the blower/vacuum cleaner. Tighten the bolts;
2. Align and fit the lower blow tube (1) into the upper blow
tube (2);
3. Place and tighten two bolts.
1. Open the zip of the collection bag and insert the elbow
tube;
2. Pass the narrow end of the tube through the small
opening in the collection bag;
3. Close the collection bag. Make sure that it is completely
closed;
To use the collection bag, you must remove the blow
tubes.
4. Align and fit the elbow tube to the air outlet of the
blower/vacuum cleaner, as if it were the upper blower
tube.
Switch off the blower/vacuum cleaner whenever you
attach the suction tubes and use it as a vacuum
cleaner.
1. Unscrew the knob (8) on the air suction cover (7);
2. Pull and hold the cover to install the upper suction tube;
3. Align the switch on the air inlet with the metal part on the
upper suction tube;
4. Turn the tube counterclockwise to secure;
5. Align and fit the lower suction tube to the upper suction
tube;
6. Place and tighten two bolts.