BFT LEO MV D Instrucciones De Uso página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
-
Radio transmitter programming (radio prog) [ ON ]
ON:
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new trans-
mitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF: This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio
menu.
6.3) Radio Menu (radio)
- Add start (add start)
Associates the required key to Start command
- Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the key
number (T1, T2, T3 or T4).
- Eliminate list (erease 64)
WARNING! Completely removes all memorised radio control devices from
the receiver memory.
- Receiver code reading (RX code)
This displays the code entered in the receiver.
6.4) Language Menu (Language)
Allows you to set the language on the display programmer.
5 languages are available:
-
ITALIAN (TA)
-
FRENCH (FRA)
-
GERMAN (DEU)
-
ENGLISH (ENG)
-
SPANISH (ESP)
6.5) MENU DEFAULT (DEFAULT)
Restores the preset default values on the control unit. After restoring, a new
autoset operation must be carried out.
6.6) DIAGNOSTICS AND MONITORING
The display on the LEO MV D panel shows some useful information, both
during normal operation and in the case of malfunctions.
Diagnostics:
In the case of malfunctions, the display shows a message indicating which
device needs to be checked:
STRT
= START input activation
STOP
= STOP input activation
PHOT
= PHOT input activation
FLT
= FAULT input activation for checked photocells
SWO
= input activation OPENING LIMIT SWITCH
SWC
= input activation CLOSING LIMIT SWITCH
OPEN
= OPEN input activation
CLS
= CLOSE input activation
BAR
= input activation SAFETY EDGE
TIME
= TIMER input activation
In the case where an obstacle is found, the LEO MV D panel stops the door
and activates a reverse manoeuvre; at the same time the display shows the
"BAR" message.
6.7) Statistics
Having connected the universal palmtop programmer to the control unit,
enter the CONTROL UNIT / STATISTICS menu and scroll the screenful
showing the statistical parameters:
-
Board microprocessor software version.
-
Number of cycles carried out. If motors are replaced, count the number
of manoeuvres carried out up to that time.
-
Number of cycles carried out from the latest maintenance operation.
It is automatically set to zero after each self-diagnosis or parameter writing.
-
Date of latest maintenance operation. To be updated manually from the
appropriate menu "Update maintenance date".
-
Installation description. 16 characters can be entered for installation
identification.
7) CONNECTION TO PARKY CAR-PARK MANAGEMENT SYSTEM
The board is provided with an output (terminal JP4) for controlling the barrier
status, configured as follows (Fig.7):
contact closed between terminals 19 and 20 with barrier lowered
contact closed between terminals 18 and 20 with barrier raised.
INSTALLATION MANUAL
8) SERIAL CONNECTION USING SCS1 BOARD (Fig.5)
The LEO-MV-D control panel allows several automation units (SCS1) to be
connected in a centralised way by means of appropriate serial inputs and
outputs. This makes it possible to use one single command to open and
close all the automation units connected.
Following the diagram in Fig.5, proceed to connecting all the LEO-MV-D
control panels, exclusively using a telephone-type line.
Should a telephone cable with more than one pair be needed, it is indispens-
able to use wires from the same pair.
The length of the telephone cable between one appliance and the next must
not exceed 250 m.
At this point, each of the LEO-MV-D control panels must be appropriately
configured, by setting a MASTER unit first of all, which will have control over
all the others, to be necessarily set as SLAVE (see logic menu).
Also set the Zone number (see parameter menu) between 0 and 127.
The zone number allows you to create groups of automation units, each one
answering to the Zone Master unit. Each zone can only be assigned one
Master unit, the Master unit in zone 0 also controls the Slave units in
the other zones.
8.1) Opposite barriers/gates (Fig.6)
Only with 3.7 or later microprocessor version.
By means of a serial connection, it is also possible to obtain centralised
control of two opposite barriers/gates.
In this case, the Master M1 control panel will simultaneously manage closing
and opening for the Slave M2 control panel.
SETTING REQUIRED FOR OPERATION:
- MASTER board: zone=128, master=ON
- SLAVE board: zone=128, master=OFF
WIRING REQUIRED FOR OPERATION:
- The MASTER and SLAVE control units are interconnected through the 4
wires (RX/TX) for the SCS1 interface boards;
- All the activation controls, as well as the remote controls must refer to the
MASTER board;
- All the photocells (checked or unchecked) must be connected to the MAS-
TER control panel;
- The safety edges (checked or unchecked) of the MASTER leaf must be
connected to the MASTER control unit;
- The safety edges (checked or unchecked) of the SLAVE leaf must be con-
nected to the SLAVE control unit.
9) SCRAPPING
Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular
risks or danger. In case of recovered materials, these should be sorted out
by type (electrical components, copper, aluminium, plastic etc.).
10) DISMANTLING
WARNING: before opening the door, make sure that the spring has
been unloaded (rod at 43°). When the automation system is disassembled
to be reassembled on another site, proceed as follows:
-
Disconnect the power supply and the entire electrical installation.
-
Remove the actuator from its fixing base.
-
Disassemble all the installation components.
-
In the case where some of the components cannot be removed or are
damaged, they must be replaced.
WARNINGS
Correct controller operation is only ensured when the data contained in
the present manual are observed. The company is not to be held respon-
sible for any damage resulting from failure to observe the installation
standards and the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
ENGLISH
13
LEO MV D - Ver. 04 -

Publicidad

Tabla de contenido
loading

Tabla de contenido