EN
7.
Remove the impeller shaft with pulley assembly
attached.
8.
Remove the damaged impeller. Make sure that
the shaft sleeve on the left side of the shaft is not
missing.
9.
Install the impeller shaft with pulley assembly
attached in the new impeller. Make sure that you
replace the retained shaft sleeve on the left side
of the shaft.
English
10. Replace and tighten the remaining nut on the left
side plate assembly, screws on the left side cover
and screws on the pulley assembly.
11. Put the belt and the belt tensioner into position.