INSTALLATION MODE
The electric lock/ alarms / Cameras are not included in the package; you can
purchase an electric lock which is suitable for actual requirement
In the standard delivery the system supports locks with normally open (N.O.) door
unlocking method. It means that in the normal state the dry contact is opened so the lock
is kept under constant closed state. If the unlocking push-button is pressed and the dry
contact is changed to colset, then the lock is released
Indoor machine power with a built-in power or an external power optional. Please refer to
actual control using. If the indoor machin with a built-in power source, applicable to wide
voltage range (AC 100V-240V). Please first pull out the AC power plug before the
installation of the device. As shown below
Please refer to the following for use and selection of the wires (cable quality affects video
and voice transfer distance).
1 4C Ordinary unshielded and shielded wire connection modes:
Distance ≤28m(4*0.2mm²); Distance ≤50m(4*0.3mm²); Distance ≤80m(4*0.5mm²)
2. 3C Normal unshielded connection mode + video wire
3. 5c network cable connection mode: (not recommended)
EN
WIRING DIAGRAM
4C
CAM1
Alarm
CAM2
Alarm
(≤100m)
Unshielded wire connection(≤ 50mt )
4C
4C
4C
4C
4C
4C