Descargar Imprimir esta página

Taurus CIGE5FIXMF Instrucciones De Uso página 50

Publicidad

Downloaded by: pd-oliana on 07-03-2023 10:49 CET
GAS HOSE PASSAGE WAY
Connect the appliance to the gas piping tap in shortest possible route and in a way that ensure no gas leak-
age will occur.
In order to carry on a tightness and sealing safety check ensure that the knobs on the control panel are
closed and the gas cylindir is open.
WARNING: While performing a gas leakage check, never use any kind of lighter, match, cigarette or similar
burning substance.
Apply soap bubble on the connection points. If there is any kind of leakage then it will cause bubbling.
While inserting the appliance in place ensure that it is on the same level with the worktop. If required adjust
the legs inorder the make level with the worktop.
Use the appliance on a level surface and in a well ventilated environment.
WARNING: Before placint the appliance, check that the local distribution conditions (gas type and pressure)
conform to the product settings.
Nozzle change operation
1. Please use driver with special head for removed and install nozzle as. (figure 3)
2. Please remove nozzle (figure 4) from burner with special nozzle driver
and install new nozzle. (figure 5)
Figure 3
VENTILATION OF ROOM
The air needed for burning is received from room air and the gases emitted are given directly in room. For safe
operation of your product, good room ventilation is a precondition. If no window or room to be utilized for
room ventilation is available, additional ventilation should be installed. However, room has a door opening
outside, it is no needed to vent holes.
Room size
Smaller than 5 m³
Between 5 m³ - 10 m³
Bigger than 10 m³
In basement or cellar
REDUCED GAS FLOW RATE SETTING FOR HOB TAPS
1. Ignite the burner that is to be adjustment and turn the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjustment screw. For LPG (butane-pro
pane) turn the screw clockwise. For the naturel gas, you should turn the screw counter- clockwise once.
"The normal length of a straight flame in the reduced position should be 6-7 mm."
4. If the flame is higher then the desired position, turn the screw clockwise. If it is smaller turn anticolockwise.
5. For the last control, bring the burner both to higt-flame and reduced positions and check whether the
flame is on or off.
Depending on the type of gas tap used in your appliance the adjustment screw position may vary.
To adjust your oven acc. to the gas type, make the adjustment for reduced flame carefully by turning
Figure 4
Ventilating opening
Figure 5
min. 100 cm²
min. 50 cm²
no need
min. 65 cm²

Publicidad

loading