CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT, THEREFORE, NOT POWERED. MORE-
OVER, WE RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3°C IF YOU INTEND TO USE
THE COMFORT CLIMA FUNCTION.
Loading the auger
Comfort climate
Carry out this operation to facilitate stove's first start operations; You should also check that you have introduced pellets
The activation of this function enables the stove to reduce pellet consumption by activating the modulation phases, after the desired
into the hopper and wait until the stove is in "SHUTDOWN" or "FINAL CLEANING" mode. The number expressed in sec-
Feed screw loading
temperature has been reached. Subsequently, the stove checks that the temperature is maintained steady for a preset time. If this
onds indicates the rotation time of the infeed screw during the first loading cycle. Once this time has elapsed, the infeed
Before starting the stove for the first time, whenever the stove is in alarm "06 - Pellets finished", and in any case whenever the hopper
screw stops immediately and then pellets are emptied from the grate before turning on the equipment.
condition is met, it automatically switches off, and on display appears the writing ECO.
has emptied completely, the initial feed screw loading is required. This phase involves filling the pellet loading system so that when
The stove turns on again when the temperature drops below the set threshold.
the system is started, it is ready to load the pellets into the brazier.
Below are given the steps for accessing the relative menu.
In the event that the feed screw operations are not carried out, there may be stove ignition failures.
Below are given the steps for accessing the relative menu.
MANUFACTURER
MANUFACTURER
ENGINEER
Press the key "access
menu" to access
the
MENU page
Press the "menu access"
Press the key
"access menu" to
At the end of the auger loading, the display shows 0 "and automatically switches to the USER menu page.
button to access the
access
the
MENU screen.
MENU page
Press the key for several times until the Stand-by page is displayed.
THE PRE-SET INITIAL LOADING TIME IS SUCH TO ALSO INCLUDE ENOUGH PELLETS FOR THE FIRST IGNITION.
ALWAYS EMPTY THE BRAZIER BEFORE TURNING THE STOVE ON AND ALWAYS CHECK
AFTER THE INITIAL LOADING OPERATIONS, NO BRAZIER CLEANING WILL PRECEDE THE IGNITION PHASE.
THAT ALL NONE OF ITS HOLES IS CLOGGED NEVER EMPTY THE RBAZIER INSIDE THE HOPPER.
Once you have accessed the Climate Comfort menu, it is possible to operate on the 3 types of settings dedicated to the function:
FIRE HAZARD.
Setting operating temperature and power:
COMFORT CLIMA
Setting operating temperature and power:
Set the two values following the indications given in the chapter "Description of thr display"
Set the two values following the indications given in the chapter "Description of thr display"
ENABLE COMFORT
Turning the device on
Turning the device on
RESTART DELTA
Keep the key ON/OFF pressed for a few seconds to turn on the stove.
Keep the key ON/OFF pressed for a few seconds to turn on the stove.
SHUTDOWN DELAY
The appearance of the message "ADJUST THE RDS SYSTEM" indicates that the initial parameter testing procedure
and calibration has been unsuccessfully. This indication does not cause stove blockage (see the SIGNALLING POP UP
COMFORT CLIMA
section).
On the display of the handheld set appears the following:
ENABLE COMFORT
RESTART DELTA
SHUTDOWN DELAY
COMFORT CLIMA
ENABLE COMFORT
Press and hold the ON/OFF button to turn off the stove door, and reset any alarms triggered.
RESTART DELTA
In case the infeed screw operations described avobe have not been executed, the stove may fail to turn on. In this case,
SHUTDOWN DELAY
carry out the operations described above and empty the brazier and reset the alarm.
If the stove still fails to turn on, check that the grate is properly installed and perfectly adherent to the base, and also check that
Press the key for several times until the Stand-by page is displayed.
there are no deposits that prevent the smooth passage of air to enable ignition. If the problem persists, contact the support ser-
vice.
Sequence of ignition phases
What happens if the batteries are empty?
User's manual HANDHELD TOUCH RADIO
Use and maintenance manual Vela 11
MENU
USER
MENU
ENGINEER
USER
Press the key
"confirm"
to access the
Press the "confirm"
USER page
Press the key
button to access the
"confirm"
to access the
USER screen
USER page
SWITCH-ON- initial pellet loading phase;
WAIT FLAME - flame
development wait
phase;
FLAME PRESENT - flame stabilization
phase and reduction of combustible
inside the brazier;
If the battery is discharged, within the
"drop" is shown a symbol that indicates
that the battery is empty, while maintain-
ing active the features of your device.
USER
SCREW FEEDING
USER
CHRONOTHERMOSTAT
AIR-PELLET SET
SCREW FEEDING
CHRONOTHERMOSTAT
STOVE STATE
AIR-PELLET SET
STOVE STATE
ENABLE COMFORT
COMFORT CLIMA DELTA
SHUTDOWN DELAY
Vers. 01 of:07.04.14
Page 63
SCREW FEEDING
COMFORT CLIMA
SETTINGS
Press CONFIRM to enable
the rotation of the auger
Press the "confirm"
Press the key "selection" for
"selection"
button to activate feed
to switch to the second page
screw rotation
of USER MENU and select
CLIMATE COMFORT.
ENABLE COMFORT
COMFORT CLIMA DELTA
SHUTDOWN DELAY
WORK - operation phase
described in
the dedicated chapter;
As soon as the level of the battery
prevents the radio communication the
handheld set displays on full screen the
picture of empty battery and all device
functions are locked until the batteries
are replaced
Rev.1 09.02.18
Pag.22
EN
USER