Descargar Imprimir esta página

AL-KO B800 Li Instrucciones De Operación página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
Charging the rechargeable battery
Charge status indicators on the rechargeable
battery (01)
LEDs
LEDs (2), (3) and (4)
light up.
LEDs (3) and (4) light
up.
LED (4) lights up.
9 HELP IN CASE OF MALFUNCTION
NOTE How to determine the charge status is
described in the operating instructions for the re-
chargeable battery.
Errors occurring
Rechargeable battery is
not charging.
443549_a
Charge status of the
rechargeable battery
Rechargeable battery
is fully charged, i.e. to
100%.
Rechargeable battery
is 66% charged.
Rechargeable battery
is 33% charged.
Displays
LED on the charger for
the left or right battery
compartment lights up
red continuously.
LED on the charger for
the left or right battery
compartment flashes
red.
The LED for mains volt-
age on the charger is
not active.
LEDs
LED (5) lights up.
LED (5) flashes.
8 CHARGING THE RECHARGEABLE
BATTERY
The process of charging the battery is described
in the operating instructions 443551 "C200 Li du-
al charger" and 441633 "C130 Li charger".
NOTE For malfunctions that are not listed in
this table or that you cannot resolve yourself,
please contact our customer service.
Possible cause
The service life of the
battery has expired.
The rechargeable bat-
tery is not fully inserted
in the charger.
The plug contacts of
the rechargeable bat-
tery or charger are
soiled.
The rechargeable bat-
tery or charger is faulty.
The rechargeable bat-
tery or charger is too
hot.
No mains voltage.
Charge status of the
rechargeable battery
The rechargeable bat-
tery is defective.
Rechargeable battery
is overheated.
Solution
Replace the battery.
Use only OEM acces-
sories.
Fully insert the re-
chargeable battery in
the charger.
Disconnect the power
plug and clean the plug
contacts with a dry
cloth. If the fault occurs
again, contact a service
centre of the manufac-
turer.
Replace the recharge-
able battery or charging
unit. Use only OEM ac-
cessories.
Disconnect the power
plug and let the re-
chargeable battery and
charger cool down.
Keep the ventilation
slots of the charger
clear.
Insert the mains plug or
check that mains volt-
age is present.
15

Publicidad

loading