On 2nd IHC
On the 2nd IHC access the settings menu, by pressing and holding the rotary knob for 3 seconds until „SEt" is displayed, then rele-
ase. When the surface temperature limitation is displayed briefly press the rotary knob two times until "BOX" is displayed.
While "BOX" is displayed turn the rotary knob to initiate the pairing process.
After successful, both IHCs display "ok" for 5s and the connection status icon turns on.
An additional connect box (gateway) is not necessary to connect 2 IHCs with each other.
Further IHCs can then be added afterwards.
To do this, first repeat the process according to section 1st IHC on one of the IHCs already connected and then repeat the steps according
to 2nd IHC on the IHC to be newly added.
English
6.2 Pairing RCE with connected IHCs
Multiple connected IHCs can also be controlled centrally via a remote control easy. To do so, first connect 2 or more IHC as described
in section 6.1.
Afterwards, access the settings menu on one of the IHCs, by pressing and holding the rotary knob for 3 seconds until „SEt" is display-
ed, then release. When the surface temperature limitation is displayed briefly press the rotary knob until "rC" is displayed.
While "rC" is displayed turn the rotary knob. The pairing process starts for 60s, during this time press any button on the RCE.
After successful pairing, IHC and RCE display "ok" for 5s and the connection status icon turns on.
40