3. Proper use

The shielding gas welding set is exclusively desi-
gned for welding steel with the MAG (Metal Active
Gas) method using the appropriate welding wires
and gases.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case
of misuse. The user / operator and not the manu-
facturer will be liable for any damage or injuries of
any kind caused as a result of this.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Symbols and technical data

EN 60974-1
European standard for arc welding sets and wel-
ding power supplies with limited on time
U
0
Rated idling voltage
U
1
Mains voltage
Ø mm
Welding wire diameter
I
1max
Rated maximum mains current
I
2
Welding current
~ 50 Hz
Mains frequency
IP 21
Protection type
Anl_TC_GW_190_D_SPK9.indb 26
Anl_TC_GW_190_D_SPK9.indb 26
GB
H
Insulation class
X
On-load factor
Mains connection
Metal inert and active gas welding including the
use of fi ller wire
Symbol for falling characteristic curve
Transformer
Fuse with rated value in A in the mains connec-
tion
Do not store or use the equipment in wet or damp
conditions or in the rain
Read the operating instructions carefully before
using the welding set and follow them
Mains connection: ............... 230 V/400 V ~ 50 Hz
Welding current: ...............25-160 A (max. 190 A)
Duty cycle r X%:
10 15 25 35 60
Welding current I
(A):
2
400 V:
160 130 100 85 65
230 V:
/
Rated idling voltage U
0
Max. welding wire drum: ................................5 kg
Welding wire diameter ................. 0.6/0.8/1.0 mm
Fuse: ............................................................ 16 A
Weight: .....................................................36,3 kg
The welding times apply for an ambient tempera-
ture of 40° C.
- 26 -
100
/
115 90 70 60 40 25
: ................................ 36 V