Installation
Please refer to the following pages or the circuit diagram enclosed with the
delivery for connection of the option selected by you.
4.3
Optional attachments
4.3.1
Optional brake
CAUTION
Damage to the device due to incorrect connection of the brake.
• Operate the device only when the brake is released.
• Do not tap the brake voltage parallel to the motor.
With the integrated brake you can decelerate the stroke movement of the con-
necting rod faster and optimize the static safety.
To release the brake, connect the brake coil with conductor codes X1 and X2 to
the rated voltage of the brake in accordance with the type plate.
The braking effect does not set in until the operating voltage is missing at X1
and X2.
4.3.2
Optional potentiometer
CAUTION
Damage to the device as a result of overstepping of power of the potentiometer.
• The potentiometer can be loaded to max. 0.5 W.
• The maximum contact current is 35 mA.
• The potentiometer may only be operated with direct current (DC).
The integrated potentiometer supplies information about the movement and cur-
rent position of the piston rod.
The potentiometer requires a separate voltage supply.
The resistance between connections 1 and 2 increases synchronously with ejec-
tion of the piston rod.
The screening must be applied by the customer.