Descargar Imprimir esta página

Wetrok Master Sweep 97 Plus Manual De Instrucciones Original página 60

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
Decommissioning
Storage
10.2 Disconnect battery leads
When the battery is stored for 2 months or
more without being recharged the blue battery
connection lead should be disconnected in order
to prevent the battery from deep discharging.
EN
In addition, if necessary, the battery should be
disconnected during fault correction and removal
of blockages. Protection from accidental starting
of sweeping machine.
If the battery is to be stored for 6 months or more
the battery must be fully charged in order to
retain the performance of the battery. Information
on the charging of the battery can be found in
Chapter "6.3 Charging battery" of this operating
manual.
» Keep the battery clean as a dirty battery can
lead to battery leakage via the terminals over
time.
1
Fig. 23: Open the cover
1. Pull the two flaps (1) on the front underside of
the cover (2) a short distance forwards.
2. Lift the cover (2)
60
2
1
A
3
B
4
Fig. 24: Disconnect battery leads
3. Disconnect the blue battery lead (3) from the
insertion flap (4) of the battery.
» Ensure that external influences such as the
movement of the device cannot cause the blue
battery lead (3) to contact the insertion flap (4)
(see Illustration 24 picture B).
» The red battery lead (5) remains connected.
4. Close the cover (2) and lock it over the flaps
(1).
5
3

Publicidad

loading