PROGRAMMING AUTOMATIC CLOSING TIME
This operation can be performed only if the door is in rest position (move the
shutter until bringing it back to the closed limit switch position).
After enabling the programming by setting the microswitches DIP1 and DIP2 to ON,
the operation starts by pressing the start button or the button of a previously
activated transmitter and ends by pressing again the external button or the button of
a transmitter.
The time between the two pulses will remain set (60 seconds by default)
A beep and a warning light will indicate when the programming starts and
ends.
PROGRAMMING OPERATING TIME
This operation can be performed only if the door is in rest position (move the
shutter until bringing it back to the closed limit switch position). Once the
programming has been enabled by setting the microswitch DIP2 to ON and DIP1 to
OFF, the programming will start by pressing the external button or a previously
activated transmitter. A beep and a warning light will indicate when the programming
starts and the door will open until reaching the corresponding limit switch. Once
opened, the closing command is given by pressing the external button or a
transmitter until the door reaches the closed door limit switch, when a beep and a
warning light will indicate the end of the programming. A margin of 3 seconds is
added to the actual operating time before the stop is performed in order to ensure
that the door operation is complete. (25 seconds by default both for opening and
closing)
BEACON
A 230V beacon can be connected in parallel with the opening or closing motor; the
flashing time corresponds to the working time and it is off in stand-by mode.
RESET
If, for any reason, it is necessary to retrieve the operating time and the automatic
closing factory-programmed, you must follow the process indicated below:
1 - Disconnect the power supply 230V
2 - Set the selector switchesn the following location:
DIP1 = OFF
DIP2 = ON
DIP3 = OFF
DIP4 = ON
3 - Remove any cable connected to terminal 8-9-10-11.
4 - Power the panel with 230V. A beep signals that the process is complete.
5 - Restore any cable connected to terminal 8-9-10-11.
6 - Place the DIPs in the same position in which they were before starting the
process.
14