EN
Programmable PDM input for spe-
cial functions
Radio channel 1 command selec-
tion
Select mains frequency
E iting the menu/saving
Description of level 3 para eters
·
: Input polarity
For N.O. or N.C. input polarity confi guration.
·
: Output 4 polarity, Output 5 polarity
Output polarity: The outputs can be confi gured as N.O. or N.C.. NOTE: in the event of a power failure the N.C. contact opens anyway.
·
: Output polarity
The outputs can be confi gured as N.O. or N.C.. NOTE: in the event of a power failure the N.C. contact opens anyway.
·
: Enable command during the pause time
Depending also upon other settings, the system accepts or not the commands from inputs.
·
: Special PDM functions
= PDM is used as opening enable. As long as it is not active, no opening command is accepted. Also no close command is ac-
cepted so the bollard remains open.
= The PDM functions as described in point 1, but in case of automatic logic, the pause time is reloaded.
= The PDM function enables the TERMON system. Based on the setting of the parameter, the closing or opening of the
contact activates or deactivates the TERMON system. This allow the TERMON function to be controlled by a calendar and/or
a thermostat.
·
: Pressure switch polarity
N.O.: Pressure switch type used until 2012.
N.C.: Pressure switch type used from 2013 on.
The following table gives the 4th level functions and the adjustable parameters.
= DEFAULT value set in factory.
Par
Function
Communication protocol
U-LINK mode
U-LINK adress
Modbus/RTU ID
MODBUS RTU speed
Cycles counter
Historical errors
Control unit
: None
: Opening Enable when active
: Opening Enable and pause time reset (with =), when active
: TERMON Enabled when active
: Opening Enable and pause time reset (with =), when active
: Receiver channel 1 not used
: Receiver channel 1 mapped to START
: Receiver channel 1 mapped to OPEN (with = special function)
: Value of main frequency in Hertz (Hz)
Pressing the "F" key e its the programming menu and changes are saved
4TH
8.5
LEVEL PROGRAMMING
Settable data
: disabled
: U-LINK
: Modbus/RTU
: Slave
: Master
: For Slave
: For Master
.: 19 200 baud
. 38 400 baud
Read only parameter, in thousands ( 1000)
: do not clear (keeps) the list
: clear the list
- 38 -
= parameter value set during installation: should be fi lled if
DEFAULT value is modifi ed.
.