Descargar Imprimir esta página

Neptun NPHW 5500 Manual De Instrucciones Original página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Anleitung_NPHW_5500_SPK7__ 12.03.13 08:39 Seite 10
GBR
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
2. Layout and items supplied (Fig. 1)
2.1 Layout
1. Suction connector
2. Pressure switch
3. Pressure connection (R1 female thread)
4. Pressure gauge
5. Water filler screw
6. Water drain screw
7. Filter housing
8. Filter element
9. Connection nipple approx. 33.3 mm (R1 male
thread)
10. Ventilation screw
11. Filter top
12. Connection adapter approx. 33.3 mm (R1 male
thread) and approx. 42 mm (R 1 1/4 female
thread)
13. Pressure tank
2.2 Items supplied
Open the packaging and take out the equipment
n
with care.
Remove the packaging material and any
n
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
n
Inspect the equipment and accessories for
n
transport damage.
If possible, please keep the packaging until the
n
end of the guarantee period.
IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!
Domestic waterworks
n
Water particle filter
n
Connection nipple approx. 33.3 mm (R1 male
n
thread)
Connection adapter approx. 33.3 mm (R1 male
n
thread) and approx. 42 mm (R 1 1/4 female
thread)
Original operating instructions
n
10
3. Proper use
Applications
Irrigation and watering of green areas, vegetable
n
beds and gardens.
Operation of lawn sprinklers.
n
For drawing water from ponds, streams, rainwater
n
butts, rainwater cisterns and springs
For supplying service water
n
Transport media:
For the pumping of clear water (fresh water),
n
rainwater or light suds/service water.
The maximum temperature of the fluid must not
n
exceed +35°C if the equipment is operated
permanently.
Do not use the equipment to pump inflammable,
n
gassing or explosive fluids.
The pumping of aggressive liquids (acids, alkalis,
n
silo seepage etc.) as well as liquids with abrasive
substances (sand) must likewise be avoided.
This equipment is not designed to convey
n
drinking water.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufacturer
will be liable for any damage or injuries of any kind
caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection:
Power consumption:
Pumping rate max.
Delivery head max.
Delivery pressure max.
Suction height max.
Pressure connection:
approx. 33.3 mm (R1 female thread)
Suction connection:
approx. 42 mm (1 1/4 male thread)
Water temperature max.
Tank capacity:
Cut-in pressure approx.:
230 V ~ 50 Hz
1150 W
5500 l/h
48 m
0.48 MPa (4.8 bar)
8 m
35°C
24 l
0.15 MPa (1.5 bar)

Publicidad

loading

Este manual también es adecuado para:

41.734.23