WIRING
!
WARNING
Risk of electric shock . Electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards . Before connecting
wires, switch power off at service panel and lock
service disconnecting means to prevent power from
being switched on accidentally .
1 . Using appropriate wire nuts (not included), connect house
power cable to unit wiring: BLACK to BLACK, WHITE to
both WHITE wires and GREEN or bare wire to GREEN
ground screw (FIG . 20) .
2 . Reinstall the wiring compartment cover in the unit; ensuring
the bottom tabs are inserted in their embossed location .
Secure in place using its retaining screw (FIG . 21) .
CAUTION
Take care not to pinch wires while reinstalling wiring
cover .
INSTALL THE FILTER(S)
Ducted Installation
Reinstall the grease filter(s) .
Non-Ducted Installation
PM300SS unit only: Attach the non-ducted filter (included
with the HARKPM21 non-duct kit) to the back of the
grease filter using clips (provided with non-ducted filter) .
To order a new non-ducted filter, use service part number
S99010464 .
BBN1243SS and BBN1303SS units only: Attach
the non-ducted filters (included with the HARKBN24
or HARKBN30 non-duct kit) to the back of the grease
filters using clips (provided with non-ducted filters) . To
order new non-ducted filters, use service part number
S99010464-124 for BBN1243SS and S99010464-130
for BBN1303SS model .
OPERATION
Blower Switch:
Turns blower on to LOW speed .
HQ0008
o Turns blower OFF .
HQ0033
Turns blower on to HIGH speed .
HQ0008
Light Switch:
HQ0009
Turns light ON .
o Turns light OFF .
HQ0009