5
Mounting
5 Mounting
Aids
Materials
Requirements:
•
The system has been de-energized and secured against being switched on again.
•
The mounting holes have been drilled.
chapter 4.8 "Dimensions", Page 13
•
The connecting cable is pre-assembled.
Procedure:
1. Place the thread sealing ring (1)
on the socket (2) of the cable fit-
ting.
2. Insert the cable fitting (3) into
the underside of the housing
and tighten.
Tightening torque: 2 Nm
14
Slotted screwdriver
Torque wrench with open-ended insert, wrench size 20
Cross-headed screwdriver
2 fastening screws
Connecting cable, "Electrical data ", Page 9
(1)
(2)
(3)