ADDITIONAL
INSTRUCTIONS
FOR EXPORT MODELS
(Not U.S. Mexico,
or Canada)
Contact
the distributor
that sold the appliance
or: Amana
International,
1475 East Woodfield
Road Schaumburg,
Illinois 60173 Phone:
847-273-3100,
for information
on product,
shipping
damage,
replacement
parts and accessories.
Amana
dryer
models manufactured
for operation
on 60Hz AC are not designed
for use on 50Hz AC
electrical
service
and conversion
of the product
from 60 to 50Hz operation
is not recommended.
For
additional
information on 50Hz product,
contact Amana
International.
The electric
service
reqirements
can be found on the data label located on the front of the dryer behind the door.
EXPORT
ELECTRIC
MODELS
Some export electric
models are manufactured
for operation
on 230/240
volt, 50 Hz and some for
operation
on 220 Volt, 60 Hz electric
service.
A two-wire
approved
electrical
service
with a 30-amp
fuse
or circuit
breaker
is required.
The dryer must be earthed
with an earthing
wire.
IMPORTANT:
When permitted
by local codes the dryer electrical
supply
may be connected
by means
of a power supply cord kit. The cord must marked for use with clothes
dryers,
agency
listed, rated for
240 volts - 30 amp minimum.
The cord should
be terminated
with closed
loop terminals,
open-end
spade lugs with turned
up ends or with tinned
leads.
Do not reuse a power supply cord from an old
dryer.
The power cord or electric
supply wiring
must be retained
at the dryer cabinet with a suitable
agency
listed strain relief.
2-WIRE
SYSTEM
CONNECTIONS
1. Loosen
or remove center terminal
block screw.
2. Connect
neutral
wire (White or center wire) of power supply cord to the center, silver colored
terminal
screw of the terminal
block. Tighten
screw.
3. Connect
the other wire to outer terminal
block serew. Tighten
screw.
4. Tighten
strain relief screws.
5. Insert tab of terminal
block cover into slot of dryer rear panel,
Sccure cover with hold-down
screw.
4
5
1. External
ground
connector
2. Neutral grounding
wire (green.yellow)
3. Center silver-colored
terminal
clock screw.
4. Neutral wire (white or center wire)
5. 3/4 in. (1.9 c m ) UL-listed
strain relief
6. Neutral wire (white or center wire)
BEFORE
OPERATING
OR TESTING,
be sure the
machine
is properly
grounded.
EXPORT
GAS MODELS
Some export gas models are manufactured
for operation
on 230/240
volt, 50 Hz and some for operation
on 220 volt, 60 Hz electrical
service
with a 15 amp fuse or circuit
breaker.
Export gas models have been manufactured
for use with natural gas having a higher heating value of
approximately
1025 BTU per cubic foot.
Conversion
to LP gas with a higher heating value
must be
performed
by a qualified
service
technician.
A 33002927
Natural Gas to LP Gas, 50 Hz conversion
kit is
available.
12