IMPORTANT TO INSTALLER
Please
Read The Following
Instructions
Carefully
Before Starting
To Install The Dryer. These Instructions
Should
Be Retained
For Future Reference.
REMOVE THE DOOR FROM ALL DISCARDED
APPLIANCES
SUCH AS
DRYERS TO AVOID THE DANGER
OF A CHILD SUFFOCATING.
LOCATION CONSIDERATIONS
The dryer should
be located to permit adequate
room in front for loading the dryer, and sufficient
room
behind the dryer for the exhaust
system.
This dryer is factory-ready
for rear exhaust.
To exhaust
out the bottom
or left side, use the accessory
exhaust
kit (see Accessories).
Instructions
are included
with the kit.
It is important to make sure the room has adequate
make-up
air. The area where the dryer is located must
not obstruct
the flow of combustion
or ventilating
air.
On gas dryers,
adequate
clearance
as noted on the data plate must be maintained
to insure adequate
air
for combustion
and proper operation
of the dryer.
THE DRYER
MUST NOT BE INSTALLED
OR STORED
IN AN AREA WHERE
IT WILL BE
EXPOSED
TO WATER AND/OR
WEATHER.
THE DRYER AREA
IS TO BE KEPT CLEAR AND
FREE FROM
COMBUSTIBLE
MATERIALS,
GASOLINE
AND OTHER
FLAMMABLE
VAPORS
AND
LIQUIDS.
A DRYER
PRODUCES
COMBUSTIBLE
LINT. THE AREAAROUND
THE DRYER
SHOULD
BE KEPT FREE OF LINT.
ALCOVE OR CLOSET INSTALLATION
_.WARNING1 WARNING
-
The dryer must
be exhausted
to
the outside
to
reduce
the risk
of fire when
installed in an alcove or closet.
An appliance
installed in a closet shall have no other fuel-
burning
appliance
installed in the same closet.
WARNING:
To reduce
the risk of fire, this
dryer MUST
BE EXHAUSTED
TO THE
OUTDOORS.
See EXHAUST
INFORMATION
section.
Minimum
clearances
between
dryer cabinet
and adjacent
walls or other surfaces
are:
2" front, 0" top, 0" either side and 2-3/8" rear.
Closet front must have two unobstructed
air openings
combined
total area 72 in 2 min., located 3 in
min. from top and bottom.
Louvered
door with equivalent
air opening
is acceptable.
MOBILE HOME INSTALLATION
The installation
of the dryer in mobile homes
must conform
to the Manufactured
Home
Construction
and Safety
Standard
Title 24 CFR, Part 32-80 {formerly
the Federal
standard
for Mobile Home
Construction
and Safety, Title 24, HUD (Part 280),
1975} for the United States,)
or CSA Standards
Z240
(for Canada).
When
installing
a dryer in a mobile
home, provisions
for anchoring
the dryer to the floor must
be made. An anchor
bracket
kit is available
with instructions
(see Accessories).
Locate in an area that has
adequate
make up air. A minimum
of 72 in 2 (183 cm _ ) of unobstructed
opening
is required.
All mobile
home
installations
must be exhausted
to the outside
with the exhaust
duct termination
securely
fastened
to the
mobile
home structure,
using materials
that will not support
combustion.
The exhaust
duct may not
terminate
beneath
the mobile home. See the section
on exhausting
for more information.