ELECTRICAL REQUIREMENTS
NOTE:
Wiring
diagram
is located
below the Top Cover.
Export
models
(not U.S. or Canada):
See Additional
Instructions for Export Models on the other side of this sheet.
_.WARNING
• Improper connection of the equipment grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or serviceman if you are in doubt as to whether
the appliance is properly grounded. Do not modify the plug provided with the appliance - if
it will not fit the outlet, have a proper outlet installed by a qualified electrician.
• To prevent unnecessary risk of fire, electrical shock or personal injury, all wiring
and grounding must be done in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA No. 70-Latest Revision (for the US)
or the Canadian Electrical Code CSA C22.1 - Latest Revisions and local codes and ordinances.
It is the
personal responsibility and obligation of the appliance owner to provide adequate electrical services for
this appliance
• All gas installations must be done in accordance with the national Fuel Code ANSI/Z2231 - Last revision
(for United States) or CAN/CGA - B149 Installation Codes - Latest Revision (for Canada) and local codes
and ordinances.
GROUNDING
This dryer must be grounded.
In the event of malfunction
or breakdown,
the ground will reduce the
risk of electrical
shock by providing
a path of least resistance
for electrical
current.
GAS
MODELS
This appliance
is equipped
with a cord having an equipment-grounding
conductor
and a grounding
plug.
The plug must be plugged
into an appropriate
outlet that is properly
installed
and grounded
in
accordance
with all local codes and ordinances.
Do not modify the plug provided
with the appliance
- if it will not fit the outlet,
have a proper outlet
installed
by a qualified
electrician.
If a separate
ground
is required
by local codes,
a grounding
kit (Part No. 12001875)
is available.
It
contains
ground
wire, clamp,
ground screw
and washer.
Connect
ground
wire to back of unit with the
cabinet
ground screw and washer.
Secure
other end of ground
wire to a suitable
external
ground
connection.
The wire may be secured
with the clamp to a grounded
COLD metal water pipe.
NEVER
CONNECT
GROUND
WIRE TO PLASTIC
PLUMBING
LINES,
GAS LINES OR HOT WATER
PIPES.
ELECTRIC
MODELS
This appliance
is equipped
with a cord having an equipment-grounding
conductor
and a grounding
plug.
The plug must be plugged
into an appropriate
outlet that is properly
installed
and grounded
in
accordance
with all local codes and ordinances.
If a power cord is not used and the electric dryer is to be permanently
wired, the dryer must be
connected
to a grounded
metal, permanent
wiring system; or an equipment
grounding
conductor
must
be run with the circuit conductors
and connected
to the equipment
grounding
terminal.