Descargar Imprimir esta página

Schulz bravo CSI 4 BR/AD Manual De Instrucciones página 52

Publicidad

Idiomas disponibles

Idiomas disponibles

FIGURE 6.4
• Products contained in this manual were designed and manufactured to operate in up to 1000m altitude.
For products that need to operate above this altitude, consult Table 6.1 or contact the factory to verify the
product's correct sizing under these conditions.
Alt (m)
% FS
1000
1,00
1500
1,02
2000
1,05
2500
1,09
3000
1,13
3500
1,17
4000
1,22
TABLE 6.1 SERVICE FACTOR (SF) OF THE MOTOR DUE TO THE ALTITUDE VARIATION
2. Location:
• The Compressor must be installed or used in an area that is covered, illuminated, ventilated, free of dust,
toxic gases, humidity and any other kind of pollution. Places such as stockrooms, pantries, basements, gara-
ges, bathrooms and chemically contaminated areas must be avoided.
• Establish the location of the condensate drain (this must be treated before discarded into the environment.)
Consult Chapter – ENVIRONMENTAL GUIDELINES AND RECOMMENDATIONS.
• When necessary to reduce the equipment's noise, an acoustic project should be utilized, of the customer's
responsibility.
• The maximum recommended ambient temperature for operation is 40°C and minimum of 5°C. Install an
exhaust system if necessary (Figure 6.10).
• Access to the equipment must be prohibited for people who are unfamiliar with its use.
FIGURA 6.7
To obtain the motor's new power in altitudes above 1000m, use the formula below:
Hp
(required)
Where:
Hp
(installed)
Hp
(required)
FIGURE 6.5
Product without base
= % FS x Hp
(installed)
= Motor power installed in the product.
= New motor power, considering
the increase of the service factor (SF).
50
FIGURE 6.6
Product with base
FIGURA 6.8
Multiply the product's installed
motor power according to
the altitude and the % SF
(percentage increase) of the
motor's service factor to obtain
the new power to be installed,
here called Hp
(requerid).

Publicidad