Descargar Imprimir esta página

Sweiss SKYWORKS Serie Manual De Usuario página 48

Ocultar thumbs Ver también para SKYWORKS Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

NO
Troubles
Close the breaker,
but the power light
1
isn't on
After welding machine
2
is over-heat, the fan
doesn't work
No output
gas when
Press the
test gas
torch switch,
3
no output
shielded gas
Output
gas when
test gas
Wire reel
doesn't
work
Wire-feeder
4
doesn't
work
Wire reel
works
No striking arc and
5
no output voltage
Welding stops, and
6
alarm light is on
Welding current is
run away and can be
7
not controlled
The crater current
8
can be not adjusted
9
No post-gas
Reasons
Breaker damaged
Fuse damaged
Power damaged
Fan damaged
The cable is loosen
No gas in the gas cylinder
Gas pipe leaks gas
Electromagnetic valve damaged
Control switch damaged
Control circuit damaged
Motor damaged
Control circuit damaged
The press wheel is loosen or weld wire skids
The wheel doesn't t with the diameter of weld wire
Wire reel damaged
Wire feed pipe is jammed
Tip is jammed because of splash
Output cable is connected mistakenly, or loosen
Control circuit damaged
Machine has self-protection
The potentiometer damaged
The control circuit damaged
The PCB damaged
The PCB damaged
20
SWEISSWELD.COM
Solution
Take to service center
Take to service center
Take to service center
Take to service center
Screw the cable tightly
Take to service center
Change it
Take to service center
Repair the switch
Take to service center
Take to service center
Take to service center
Press it tightly again
Change the wheel
Change it
Repair or change it
Repair or change it
Screw it down or change it
Take to service center
Check over-voltage, over-current, over-temperature,
lower-voltage and over-temperature, and solve it
Take to service center
Take to service center
Take to service center
Take to service center

Publicidad

loading

Este manual también es adecuado para: