Installation
6. Review the "Electrical requirements" section, then follow the 3 Wire system connection
instructions (Step 7) or 4 Wire system instructions (Step 8) below.
A
B
WARNING
If converting from a 4-wire electrical system to a 3-wire, you must connect the ground strap
to the terminal block support to ground the dryer frame to the neutral conductor.
NOTE
We recommend using ring terminals. If you use strap terminals, please ensure you install
them perfectly.
22 English
DV8000J-03170M-01_EN-US_150122.indd 22
7. Three Wire system instructions:
A. External ground connector
C
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E. ¾" (1.9 cm) UL-listed strain relief
D
a. Loosen or remove the center
terminal block screw.
E
b. Connect the neutral wire (white
or center wire) of the power
cord to the center, silver-colored
terminal screw of the terminal
block. Tighten screw.
c. Connect the other wires to outer
terminal block screws. Tighten
screws.
d. Tighten the strain relief screws.
e. Insert the tab of the terminal
block cover into your dryer's rear
panel slot.
Secure the cover with a hold-
down screw.