Descargar Imprimir esta página

Grohe EUROSMART COSMOPOLITAN E 36 36327001 Manual Del Usuario página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Replacement parts,
see fold-out page I (* = special accessories)
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Filters in connection hose dirty
®
Bluetooth
Connection not
• No reception/connection interrupted
possible
• Interferences in the reception area
• Obstacle in transmission path
• Water is flowing / Object detection
Interrupted while
• Interferences in the reception area
operating
• Obstacle in transmission path
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
accessory, prod. no.: 36 407) / app
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Turn back the device to receiving range
- Turn off the source of interference
(observe manufacturer´s documentation)
- Remove from radio path
- The detection zone must kept clear
- Turn off the source of interference
(observe manufacturer´s documentation)
- Remove from radio path
4

Publicidad

loading