PREPARATION
r_ PREPARING THE COUNTERTOP
Countertop cut-out dimensions
_
Back of Counter
Not less than _/ld' (2.4 cm)
21"_+ Yld'
5].5
_+0.16 cm
29"_+ Vis"
73.66 cm _+0.16 cm
8_As " min. cut-out
Not less than
lYJ'
to wail (22.2 cm)
(4.8 cm)
8z_d ' min. cut-out
to wail (22.2 cm)
Cutout the openingas shownin the diagram.Measure
carefullywhen cuttingthe countertop, m akingsurethesidesof
the openingare paralleland the front and rearcuts are exactly
perpendicular t o the sides.
Thefront of the openingmustclearthefront supportrail on
the cabinet,and the rear of the openingmustclearthe rear
supportof the cabinet.
Chamferall exposededgesof decorativelaminateto prevent
damagefrom chipping.
Radiuscorners of cutout and file to ensuresmooth edges
and preventcorner cracking.
Roughedgesinsidecornerswhich havenot beenroundedand
forcedfit cancontributeto crackingofthe countertoplaminate.
Countertopmustbe supportedwithin 3"(7.6cm)of cutout.
Forislandinstallation, m aintain17/8" minimimfrom cutoutto
front edge,17/8" minimumfrom cutoutto back edge,and
8 13/16"minimumfrom cutoutto sideedgesof countertop.
i-3] GAS AND ELECTRICAL LOCATION
The position of the electrical supply receptacle and
the gas supply pipe entering the cabinet should be
positioned as shown in the shaded areas marked below.
The cooktop is equipped with a 4 ft (1.2m) power cord,
which should reach any desired location on the cabinet
walls. The cooktop must be disconnected from the
power supply before any servicing is carried out.
3" (7.6 cm) IV]in.
F--
Electrical outlet
12" (30.5 cm)
above cabinet
7
floor (mount
on side or back
cabinet wall 3"
[7.6 cm] min.
from centedine)
-i
"t'I
i
4" (10.2 cm) (to clear toe kick area)
[]
PROVIDE ADEQUATE GAS SUPPLY
This cooktop is designed to operate on natural gas
only at 5" (12.7 cm) of water column pressure or on
LP gas at 10" (25.4cm) of water column pressure. It
is shipped from the factory set for natural gas. If you
decide to use this cooktop with LP gas, conversion
adjustments must be made by a service technician
or other qualified person.
A pressure regulator is to be connected in series
with the manifold of the cooktop and must remain
in series with the supply line, regardless of whether
natural or LP gas is being used.
For proper operation, the maximum inlet pressure
to the regulator must be no more than 10" (25.4
cm) water column pressure for natural gas, or 14"
(35.5 cm) water column pressure for LP gas. For
checking the regulator, the inlet pressure must
be at least 1" (2.5 cm) greater than the regulator
output setting. If the regulator is set for 5" (12.7 cm)
of water column pressure, the inlet pressure must
be at least 6" (15.2 cm).
For ease of installation, and if local codes permit,
the gas supply line into the cooktop should be
1/2" (13 mm) or 3/4" (19 ram)
I.D.
flexible metal
appliance connector three (0.9 m) to five feet (1.5 m)
in length.
F_ PRESSURE TESTING
The maximum gas supply pressure for the regulator
supplied on this appliance is 14" (35.5 cm) W.C. The
test pressure for checking this regulator must be
at least 6" (15.2 cm) W.C. for natural gas, and at
least 11" (27.9 cm) W.C. for LP.It is shipped from the
factory set for natural gas at 5" (12.7 cm) W.C.
This appliance and its individual shut-off valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of ½ PSIG.
This appliance must be isolated from the gas supply
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than ½ PSIG.