4.4) ERRORS:
these appear during operation, combined with a beep and flashing LED Worklights,
to notify the operator of procedural or operational errors.
Message
Error description
The pressure release button (5) was
pressed before the control parameters
ERROR
were reached (Force/Pressure).
Interruption of the signal from the NTC
NTC
ERROR
temperature probe of the battery.
FAULT
001
ERROR
ERROR
Abnormal power consumption of the mo-
ERROR
002
tor for more than 3 seconds.
001
The tool stops.
001
003
001
002
Output voltage of the pressure transmitter
001
002
is out of the pre-set range.
004
002
003
002
Failure to reach the set pressure within
003
003
30 seconds of continuous operation of
004
the machine.
003
004
Overcharging of the battery with protec-
004
tion tripping.
004
The tool stops.
Error screens are displayed for about 30 seconds before being reset, but will display repeat-
edly in the event of permanent anomalies.
5. CONNECTION TO COMPUTER (Smartool technology)
The memory card integrated in the tool records operating datafor
transfer via the USB cable supplied.
To view and manage this data, go to www.cembre.com and
register in the dedicated area, then download the free CEMBRE
software CEM_SWBT01.
Keeping the Firmware of the tool updated, via free of charge
download from here, will optimise the tool's performance.
Solution
Repeat the work cycle and wait for the
motor to stop automatically.
Replace the battery.
If the problem persists, please contact
CEMBRE.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery, then
re-start the tool.
If the error occurs frequently, contact
CEMBRE.
Repeat the work cycle; if the error occurs
frequently, contact CEMBRE.
Repeat the work cycle; if the error occurs
frequently, contact CEMBRE.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery, then
re-start the tool.
If the error occurs frequently, contact
CEMBRE.