Klein Tools CL600 is an automatically ranging true root mean square
(TRMS) digital clamp-meter that measures AC current via the clamp,
and measures AC/DC voltage, resistance, continuity, and tests diodes
via test-leads.
• Environment: Indoor. DO NOT expose to moisture, rain, or snow.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: 32° to 104°F (0° to 40°C)
• Storage Temp: 14° to 140°F (-10° to 60°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefficient: 0.1 x (Quoted Accuracy) per °C above 28°C
or below 18°C, corrections are required when ambient working
temp is outside of Accuracy Temp range
• Dimensions: 9.09" x 3.82" x 1.54" (231 x 97 x 39 mm)
• Weight: 11.8 oz. (335 g) including batteries
• Calibration: Accurate for one year
• Standards: Conforms to: UL STD 61010-1, 61010-2-032,
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• Safety Rating: CAT IV 600V, CAT III 1000V, Class 2,
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building's low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building's low-
voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
2
GENERAL SPECIFICATIONS
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-032, 61010-2-033.
IEC EN 61010-1, 61010-2-032,
61010-2-033, 61326-1.