Bosch FNH180K-16 Instrucciones De Funcionamiento Y Seguridad página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BM 2610011761 10-10:BM 2610011761 07-10.qxp 10/5/10 9:24 AM Page 13
• To drive the nail deeper, turn the
adjustment knob "too shallow" icon, see
figure 11.
4. Reload nails as described in the "Nail
Loading" section of this manual.
5. Reconnect battery pack.
Know what is behind your
W RNING
work piece. Do not fire
nails into walls or floors without assuring
the area on the opposite side is clear. A
nail could travel through the work piece,
striking someone.
jAM CLEARING
Disconnect the battery pack
W RNING
from tool before attempting
to clear a jammed nail. Such precautionary
safety measures reduce the risk of
unintentional tool operation.
If a nail becomes jammed in the nosepiece,
follow these instructions to remove the jammed
nail:
1. Release the trigger.
FIG. 12
2. Disconnect the battery from the tool.
3. Remove nails from the magazine as
described in "Nail Unloading."
4. Open the nose of the tool by pulling quick
release lever forward. Pull open the nose of
the tool to access the nail jam, see figure 12.
5. Remove the nail, using pliers if necessary.
6. Close the nose of the tool by hooking the
spring of the quick clear lever on the two
hooks on the nose. Press the lever closed,
see figure 13.
7. Reinsert nails into the magazine as
described in "Nail Loading".
8. Reconnect battery.
NOTE: If the driver blade does not return to its
up position, disconnect battery and contact a
Bosch factory service center or authorized
Bosch service station.
NOTE: If nails continue to jam frequently in the
nose piece, contact BOSCH service center for
repair.
FIG. 13
-13-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fnh180-16b

Tabla de contenido