Features
The AIRMAX+® PAPR charger is suitable for Lithium-ion battery packs only and has been
provided with a short circuit protection device. Each charger has quick-change socket
power adapter for various mains (see picture below). It is designed to quick charge 4-6
cells Lithium–Ion battery packs with a capacity of 5200mAh to 7800mAh.
AIRMAX ® charger -40363
Only use this charger with batteries that meet the specifications on the chart below:
Connect its DC output plug to the battery and then connect its AC input plug to 100-
240VAC mains power before switching on the mains power point; ensure the charging
lights are illuminated.
It is normal that the charger and the battery might warm up (below 50°C) during charging;
otherwise please stop using it. Please disconnect the charger AC input plug first and then
disconnect the DC output plug when charging is finished. The red LED shows that the
batteries are still charging. The green LED indicates that the battery is fully charged and
ready for use. Do not leave the battery charger in the power supply when not in use.
Safety
Do not charge any other batteries than the specified in this manual. Don't use the charger if
it shows visible damage. Do not attempt to repair the charger, this will end the warranty and
will increase the accident and/or damage. Never expose the charger to water, rain or snow.
Contact your supplier if charger replacement is needed.
Environmental disposal
Batteries are chemical waste, dispose them in a special container or hand them in at an
authorized recycling centre
PACKAGING / LABELING
Lot Code Description: WLyjjj-xxxx (e.g. WL0013-0005)
WL= Manufacturer identifier
y
= Last digit of year of production (e.g. 0 for 2020)
jjj = Julian (sequential) day of production (e.g. 013 for January 13)
xxxx = Last four digits of purchase order number (e.g. 0005)
• Operational range: 100Vac – 240Vac
• Frequency: 50-60Hz at 150mA
• Operating temperature range: 0°C to 40°C
• Operating relative humidity: 8% to 85%
• Operating temperature range: 0°C to 40°C
• Initial charge before first use of batteries: 8 hours
.
13
•
Operational
range: 100Vac
– 240Vac
•
Frequency:
50-60Hz at 150mA
•
Operating temperature
range: 0°C to 40°C
•
Operating relative
humidity: 8% to 85%
Initial charge before first use of batteries:
•
8 hours
Technical Specifications