•
Setting the Fan Speed
• Press [] to select:-
FAN
m
-
Low Fan Speed
FAN
mmm
-
Medium Fan Speed
FAN
iiIIm IIII
-
High Fan Speed
AUTO
FAN
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically
according to the operation.
The indoor fan stops occasionally
during
cooling operation.
•
Setting the Vertical Airflow Direction
• Press [] or [] to select:-
L
Cooling Model
J
COOL / DRY Operation
Swing up/down
Automatically
Five stages of adjustment
can be made between
14 ~ 36 angle.
FAN Operation
Move up/down
Automatically
Five stages of adjustment
can be made between
0 ~ 61 angle.
Heat Pump Model ]
COOL / DRY Operation
HEAT Operation
Swing up/down
Automatically
- When the discharge
air
temperature
is )ow such
as at the start of heating
operation, the air blows
in a horizonta) direction.
As the temperature
rises, the hot air blows
in a downward direction.
- To stop this operation,
press MANUAL.
Five stages of adjustment
can be made between
14 ~ 36 angle.
Five stages of adjustment
can be made between
0 ~ 61 angle.
•
Setting the Horizontal Airflow Direction
• Adjust it manually /
f
•
Use this air conditioner under the following
conditions:
L
Cooling
Model
1
(Unit in °F)
DBT: Dry Bulb Temp
Indoor
Outdoor
WBT: Wet Bulb Temp
DBT
WBT
DBT
WBT
Maximum Temperature
89.6
73.4
109.4
78.8
Minimum Temperature
60.8
51.8
60.8
51.8
L Heat Pump Model
]
DBT: Dry Bulb Temp
Indoor
WBT: Wet Bulb Temp
DBT
WBT
MaximumTemperature-CooUng 89.6
73.4
MaximumTemperature-Heating) (86)
(-)
Minimum Temperature-Cooling60.8 51.8
Minimum Temperature-Heating) 60.8: (-)
(Unit in °F)
Outdoor
DBT
WBT
109.4 78.8
75.21 (64.4)
60.8
51.8
(23)
(21.2)
•
Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately
2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation
is stopped, then restart immediately,
the
unit will resume operation only after 3 minutes.
•
Operation Details
COOL - Cooling
Operation
To set the room temperature at your preference
cooling comfort.
AUTO - Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature
is not displayed on the remote control
during AUTO operation.
DRY - Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification.
It does not lower the room
temperature.
During Soft Dry operation,
the indoor fan operates at
Low fan speed.
HEAT - Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
faUs, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depending on the outdoor temperature,
the operation
occasionally
stops to melt the frost on the outdoor
unit.
FAN - Air Circulation Operation
(for Cooling Model only)
When the room temperature
reaches the set
temperature,
operation commences
at Low airflow
volume. It stops when the room temperature
drops to
4°F below the set temperature.
(It is useful when using a heater).
Hi fan speed will not operate when using the air
circulation
Fan mode.