Coding
Assembly unit
A
Outdoor unit
Solar energy kit (field supply)
B
C
User interface
D
Room thermostat (field supply)
E
Boiler (field supply)
F
P_s: Solar pump (field supply)
G
P_c: Mixing pump (field supply)
H
P_o: Outside circulation pump (field supply)
I
P_d: DHW pump (field supply)
Description
Item
1
Solar energy kit signal cable
2
User interface cable
Room thermostat cable
3
Boiler control cable
4
Thenrmistor cable for T1B
5
9
DHW pump control cable
10
2-way valve control cable
3-way valve control cable
11
12
Thermistor cable
13
Booster heater control cable
15
Power supply cable for unit
16
Power supply cable for backup heater
(a) Minimum cable section AWG18 (0.75 mm
(b)The thermistor cable are delivered with the unit:if the current of the load is large, an AC contactor is needed.
Please use H07RN-F for the power wire, all the cable are connect to high voltage except for thermistor cable and cable
for user interface.
Equipment must be grounded.
All high-voltage external load, if it is metal or a grounded port, must be grounded.
All external load current is needed less than 0.2A, if the single load current is greater than 0.2A, the load must be controlled
through AC contactor.
AHS1" "AHS2", "A1" "A2", "R1" "R1" and "DTF1" "DTF2" wiring terminal ports provide only the switch signal.
Please refer to image of 9.7.6 to get the ports position in the unit.
Expansion valve E-Heating tape,Plate heat exchanger E-Heating tape and Flow switch E-Heating tape share a control port.
10
3
6
9
1-phase 12~16kW
3-phase 12~16kW
Coding
J
K
L
M
N
O
P
Q
AC/DC
Required number of conductors
AC
2
AC
5
AC
2 or 3
/
2
DC
2
AC
2
AC
2
AC
2 or 3
DC
2
AC
2
2+GND(1-Phase)
AC
3+GND(3-Phase)
2+GND(1-Phase)
AC
3+GND(3-Phase)
).
2
NOTE
Coding
1
2
3
1
2
4
5
4
5
6
7
8
7
8
9
10
133
Assembly unit
SV2: 2-way valve (field supply)
SV1: 3-way valve for domestic hot
water tank (field supply)
Domestic hot water tank
Booster heater
Contactor
Power supply
Backup heater
Zone2 SV3(3-way valve)
Maximum running current
200mA
200mA
200mA(a)
200mA
(b)
200mA(a)
200mA(a)
200mAC
(b)
200mA(a)
31A (1-Phase)
15A (3-Phase)
14A (1-Phase)
6A (3-Phase)
Assembly unit
High voltage wire hole
Low voltage wire hole
High voltage wire hole
Compressor connection port W
Drainage pipe hole
Low voltage wire hole
Low voltage wire hole(backup)
Low voltage wire hole(backup)
Water inlet
Water outlet